Fluke 83
Afhent selv
12-03-2025
13-03-2025
Specifications
Voltage DC Maximum Voltage: 1000V
Accuracy: Fluke 83 V: ±(0.1%+1)
Maximum Resolution: Fluke 83 V: 100 µV
Voltage AC Maximum Voltage: 1000V
Accuracy: Fluke 83 V: ±(0.5%+2)
AC Bandwidth Fluke 83 V: 5kHz
Maximum Resolution: 0.1 mV
Current DC Maximum Amps: 10A (20 A for 30 seconds maximum)
Amps Accuracy: Fluke 83 V: ±(0.4%+2)
Maximum Resolution: Fluke 83 V: 0.01 mA
Current AC Maximum Amps: 10A (20 A for 30 seconds maximum)
Amps Accuracy: Fluke 83 V: ±(1.2%+2)
Maximum Resolution: 0.1 µA
Resistance Maximum Resistance: 50 MO
Accuracy: Fluke 83 V: ±(0.4%+1)
Maximum Resolution: 0.1O
Capacitance Maximum Capacitance 9,999 µF
Accuracy ±(1%+2)
Maximum Resolution 0.01 nF
Frequency Maximum Frequency 200 kHz
Accuracy ±(0.005%+1)
Maximum Resolution 0.01 Hz
Duty Cycle Maximum Duty Cycle 99.9%
Accuracy ±(0.2% per khz +0.1%)
Maximum Resolution 0.1%
80 BK Temperature Probe -40.0°C - 260°C
-40.0°F - 500°F, 2.2°C or 2% whichever is greater
Conductance Maximum Conductance 60.00 nS
Accuracy ±(1.0%+10)
Maximum Resolution 0.01 nS
Diode Range: 3 V
Resolution: 1 mV
Accuracy: ± (2 % + 1)
Duty Cycle Range Accuracy: Within ± (0.2% per kHz + 0.1 %)
Environmental Specifications
Operating Temperature -20°C to +55°C
Storage Temperature -40°C to +60°C
Humidity (Without Condensation) 0% - 90% (0°C - 35°C)
0% - 70% (35°C - 55°C)
Operating Altitude 2000 m
Safety Specifications
Overvoltage category EN 61010-1 to 1000 V CAT III, 600V CAT IV
Agency Approvals UL, CSA, TÜV, VDE listed
Mechanical & General Specifications
Size 201 x 98 x 52 mm (with holster)
Weight 355 g
Weigh With Holster and Flex-Stand 624 g
Display Digital: 6000 counts updates 4/sec.
Analog: 32 segments, updates 40/sec.
Frequency: 19,999 counts, updates 3/sec at > 10 Hz.
Warranty Lifetime
Battery Life Alkaline: ~400 hours typical, without backlight
Shock 1 Meter drop per IEC 61010-1:2001
Vibration Per MIL-PRF-28800 for a Class 2 instrument